تایمر آنالوگ امرن H3CR-A8
تایمر آنالوگ امرن
مدل: H3CR-A8
تایمر آنالوگ امرن H3CR-A8
ساخت شرکت Omron ژاپن.
Omron Solid-state Multi-functional Timers
MODEL: H3CR-A8
• A wide AC/DC power supply range greatly reduces the number of timer models kept in stock.
• A wide range of applications with multiple operating modes, eight modes for 11-pin models and five modes for 8-pin models.
• Ecological design with reduced current consumption.
• Easy sequence checking with instantaneous outputs for a zero set value.
• Length of 75 mm or less when panel-mounted with a P3G-08 Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC)
• PNP input models available.
• Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.
توضیحات بیشتر
General
Item | H3CR-A/-AS/-A-301 | H3CR-AP | H3CR-A8/-A8S/-A8-301 | H3CR-A8E |
---|---|---|---|---|
Operating mode | A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot |
A: ON-delay (power supply start) B: Flicker OFF start (power supply start) B2: Flicker ON start (power supply start) E: Interval (power supply start) J: One-shot (power supply start) |
||
Pin type | ۱۱-pin | ۸-pin | ||
Input type | No-voltage input | Voltage input | — | |
Time-limit output type | H3CR-A/-A8/-AP/-A-301/-A8-301: Relay output (DPDT) H3CR-AS/-A8S: Transistor output (NPN/PNP universal) * |
Relay output (SPDT) |
||
Instantaneous output type |
— | Relay output (SPDT) |
||
Mounting method | DIN track mounting, surface mounting, and flush mounting | |||
Approved standards | UL508, CSA C22.2 No.14, NK, Lloyds, CCC Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1 for Timers with Contact Outputs. Output category according to EN60947-5-2 for Timers with Transistor Outputs. |
For details, refer to your OMRON website.
Time Ranges
operate instantaneously at all time range settings.
For details, refer to your OMRON website.
Standard (0.05-s to 300-h) Models
Time unit | s (sec) | ×۱۰ s (10 sec) | min (min) | ×۱۰ min (10 min) | h (hrs) | ×۱۰ h (10 hrs) | |
---|---|---|---|---|---|---|---|
Full scale setting |
۱.۲ | ۰.۰۵ to 1.2 | ۱.۲ to 12 | ۰.۱۲ to 1.2 | ۱.۲ to 12 | ۰.۱۲ to 1.2 | ۱.۲ to 12 |
۳ | ۰.۳ to 3 | ۳ to 30 | ۰.۳ to 3 | ۳ to 30 | ۰.۳ to 3 | ۳ to 30 | |
۱۲ | ۱.۲ to 12 | ۱۲ to 120 | ۱.۲ to 12 | ۱۲ to 120 | ۱.۲ to 12 | ۱۲ to 120 | |
۳۰ | ۳ to 30 | ۳۰ to 300 | ۳ to 30 | ۳۰ to 300 | ۳ to 30 | ۳۰ to 300 |
Double (0.1-s to 600-h) Models
Time unit | s (sec) | ×۱۰ s (10 sec) | min (min) | ×۱۰ min (10 min) | h (hrs) | ×۱۰ h (10 hrs) | |
---|---|---|---|---|---|---|---|
Full scale setting |
۲.۴ | ۰.۱ to 2.4 | ۲.۴ to 24 | ۰.۲۴ to 2.4 | ۲.۴ to 24 | ۰.۲۴ to 2.4 | ۲.۴ to 24 |
۶ | ۰.۶ to 6 | ۶ to 60 | ۰.۶ to 6 | ۶ to 60 | ۰.۶ to 6 | ۶ to 60 | |
۲۴ | ۲.۴ to 24 | ۲۴ to 240 | ۲.۴ to 24 | ۲۴ to 240 | ۲.۴ to 24 | ۲۴ to 240 | |
۶۰ | ۶ to 60 | ۶۰ to 600 | ۶ to 60 | ۶۰ to 600 | ۶ to 60 | ۶۰ to 600 |
Ratings
Rated supply voltage *۱ *۲ *۵ |
۱۰۰ to 240 VAC (50/60 Hz)/100 to 125 VDC, 24 to 48 VAC (50/60 Hz)/ ۱۲ to 48 VDC (24 to 48 VAC/VDC for H3CR-A8E) *3 |
---|---|
Operating voltage range | ۸۵% to 110% of rated supply voltage (90% to 110% at 12 VDC) |
Power reset | Minimum power-opening time: 0.1 s |
Input *6 | No-voltage Input ON impedance: 1 kΩ max. ON residual voltage: 1 V max. OFF impedance: 100 kΩ min. Voltage Input Max. permissible capacitance between inputs lines (terminals 6 and 7): 1,200 pF Load connectable in parallel with inputs (terminals 6 and 7). ۱۰۰ to 240 VAC/100 to 125 VDC High (logic) level: 85 to 264 VAC/85 to 137.5 VDC Low (logic) level: 0 to 10 VAC/0 to 10 VDC ۲۴ to 48 VAC/12 to 48 VDC High (logic) level: 20.4 to 52.8 VAC/10.8 to 52.8 VDC Low (logic) level: 0 to 2.4 VAC/0 to 1.2 VDC |
Power consumption | H3CR-A/-A8 ۱۰۰ to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz) Relay ON: approx. 2.0 VA (1.6 W), Relay OFF: approx. 1.3 VA (1.1 W) ۲۴ to 48 VAC/12 to 48 VDC (When at 24 VDC) Relay ON: approx. 0.8 W, Relay OFF: approx. 0.2 W H3CR-AP *3 ۱۰۰ to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz) Relay ON: approx. 2.5 VA (2.2 W) *4, Relay OFF: approx. 1.8 VA (1.7 W) *4 ۲۴ to 48 VAC/12 to 48 VDC (When at 24 VDC) Relay ON: approx. 0.9 W *4, Relay OFF: approx. 0.3 W *4 H3CR-A8E ۱۰۰ to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz) Relay ON/OFF: approx. 2 VA (0.9 W) ۲۴ to 48 VAC/VDC (When at 24 VDC) Relay ON/OFF: approx. 0.9 W H3CR-AS/-A8S ۲۴ to 48 VAC/12 to 48 VDC (When at 24 VDC) Output ON: 0.3 W, Output OFF: 0.2 W |
Control outputs | Models with Contact Outputs H3CR-A/-A8/-AP ۵A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = ۱) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E ۵A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = ۱) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn Transistor output: Open collector(NPN/PNP) H3CR-AS/-A8S ۱۰۰ mA max at 30 VDC max., residual voltage: 2 VDC max. |
*۲. Do not use an inverter output as the power supply. Refer to your OMRON website for details.
*۳. Models with 24-to-48-VAC or 12-to-48-VDC power supply have inrush current. Caution is thus required when turning
ON and OFF power to the Timer with a non-contact output from a device such as a sensor. (Models with an inrush
current of approximately 50 mA and a 24-VDC power supply are available (the H3CR-A-302 and H3CR-A8-302).)
For details, consult your OMRON sales representative.
*۴. The values are for when the terminals 2 and 7 and terminals 10 and 6 are short-circuited, and include the
consumption current of the input circuit.
*۵. Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.
*۶. For details, see Input Connections: No-voltage Input Signal Levels on Catalog, and Input Connections: Voltage Input
Signal Levels on Catalog.
Characteristics
Accuracy of operating time |
±۰.۲% FS max. (±۰.۲%±۱۰ ms max. in a range of 1.2 s or 3 s) |
---|---|
Setting error | ±۵% FS ±۵۰ ms *1 |
Reset time | Min. power-opening time: 0.1 s max. Min. pulse width: 0.05 s (H3CR-A/-AS) |
Reset voltage | ۱۰% max. of rated supply voltage |
Influence of voltage *2 | ±۰.۲% FS max. (±۰.۲%±۱۰ ms max. in a range of 1.2 s or 3 s) |
Influence of temperature | ±۱% FS max. (±۱%±۱۰ ms max. in a range of 1.2 s or 3 s) |
Insulation resistance | ۱۰۰ MΩ min. (at 500 VDC) |
Dielectric strength | ۲,۰۰۰ VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) ۲,۰۰۰ VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between control output terminals and operating circuit) ۲,۰۰۰ VAC, 50/60 Hz for 1 min (between contacts of different polarities) ۱,۰۰۰ VAC, 50/60 Hz for 1 min (between contacts not located next to each other) ۲,۰۰۰ VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit) for H3CR-AP |
Impulse withstand voltage |
۵ kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC ۵ kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and ۲۴ to 48 VAC/VDC |
Noise immunity | ±۱.۵ kV (between power terminals) and ±۶۰۰ V (between no-voltage input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Malfunction: 8 kV Destruction: 15 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each |
Shock resistance | Destruction: 1,000 m/s۲ 3 times each in 6 directions Malfunction: 100 m/s۲ 3 times each in 6 directions |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
Life expectancy *4 | Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) *3 |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
Case color | Light gray (Munsell 5Y7/1) |
Degree of protection | IP40 (panel surface) |
Weight | Approx. 90 g |
*۱. The value is ±۵% FS +100 ms to −۰ ms max. when the C, D, or G mode signal of the H3CR-AP is OFF.
*۲. The influence of voltage of the H3CR-A8E (24 to 48 VAC/12 to 48 VDC) is ±۲.۰% FS max. with a single-phase power
supply with fullwave rectification.
*۳. Refer to the Life-test Curve (Reference).
*۴. Contact output only.